    Automatic Control Lighting Micro Data Center For Computing R134a

    Ask Lasest Price
    Brand Name : COOLNET
    Model Number : EC20 ERx
    Certification : CE ISO
    Price : USD3000-10000/PCS
    Payment Terms : L/C, T/T
    Supply Ability : 200 SETS PER MONTH
    Delivery Time : 20-35working days
    • Product Details
    • Company Profile

    Automatic Control Lighting Micro Data Center For Computing R134a

    Automatic Control Lighting Micro Data Center Providing Integrated Solutions For Computing


    Product Introduction

    The integrated cabinet is an in-depth integration of data center infrastructure product which includes UPS, PDU system, cooling, fire protection and other subsystems. Through the monitoring system, all these subsystems could be managed which could simplify the panning and construction progress.

    Coolnet MDC Edge Micro Data Center is Coolnet's latest all-in-one solution for data centers which is also ideal for edge computing in order to reduce latency and improve network security. In addition, the micro data center has the characteristics of plug-and-play, independence and overall strength, which can save network costs to a large extent.

    Advantages of Coolnet MDC

    Area saving: integrated design, covering an area of more than 40% less than traditional construction mode;Saving supporting investment: fully enclosed design, can be installed in various environments (computer room, utility room, office, etc.), without special investment in the construction of computer room and supporting facilities.

    Reduce costs. With micro data centers, businesses don't have to concentrate upfront capital expenditures on traditional server hardware. Compared to enterprise data centers, the operating expenses of micro data centers are much lower. Additionally, the distance between client and server computers reduces the higher power costs associated with transferring computations to centralized data centers.

    Available. The reliable UPS power supply and distribution system continuously escorts IT equipment, and can also customize a highly reliable system architecture that meets the national standard A and B standards to meet the availability requirements of different users.

    Greater elasticity. Traditional data centers are often at risk of service disruption if priority lines are damaged. Even with network redundancy in place, traditional data centers will struggle to compete with the options of micro data centers in the event of a failure. Micro data centers may have dozens of failover strategies.

    A flexible infrastructure approach. Depending on demand, businesses can choose to scale their data needs up or down. The scalability of a micro data center makes it easy to align with enterprise goals.


    Feature

    Cooling System

    1. 3.5-10.5KW cooling capacity, accuracy ±0.5℃
    2.Inverter compressor + double EC fan, PUE≤1.4
    3. Low load anti-condensation technology
    4.N+X redundant group control


    Power Distribution System


    1. 3-30KVA capacity optional
    2. Rack mount
    3. Backup power time customized (15-120m)
    4. ATS dual input switch (optional)
    5. Industrial-grade devices, built-in C-level lightning protection
    6. Comprehensive monitoring, real-time power display

    Customer Benefits

    · Standard 42U cabinet, smart PDU, smart lock, beautiful appearance;
    · Customize the monitoring interface and product appearance, and increase the authority management function;
    · The whole machine is packed and transported by land for a total of 1600 kilometers, and the installation and commissioning are completed in 1 hour on site

    Technical Parameter


    ModelEC08EC12EC20ERx
    Power3KVA3-6KVA6-30KVA
    Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
    Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
    Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
    RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
    Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

    Factory View





    Q: How to deal with any inferior -quality goods ?

    A: Goods can be return back with our charge of post fee for any bad quality products within guarantee time.


    Quality Automatic Control Lighting Micro Data Center For Computing R134a for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hefei Coolnet power Co., ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)