    UPS In Row Air Conditioners Involved In Modular Data Center Solutions

    Ask Lasest Price
    Brand Name : COOLNET
    Model Number : MDC
    Certification : CE,ISO
    Price : 1800-30000USD
    Payment Terms : T/T, L/C
    Supply Ability : 300 PCS PER MONTG
    Delivery Time : 10-25 working days
    • Product Details
    • Company Profile

    UPS In Row Air Conditioners Involved In Modular Data Center Solutions

    Modular UPS In-Row Air Conditioners Involved In Modular Data Center Solutions


    Product Introduction

    Modular data centers are designed to cope with changes in servers such as cloud computing, virtualization, centralization, and high density, improve the operational efficiency of data centers, reduce energy consumption, and achieve rapid capacity expansion without affecting each other. A modular data center refers to a plurality of modules with independent functions and unified input and output interfaces, and modules in different areas can back up each other, and form a complete data center through the arrangement and combination of related modules. Modular data center is an integrated, standard, optimal, intelligent, highly adaptable infrastructure environment and high-availability computing environment.


    Benefits

    Main System Introduction

    Modular Aisle Containment
    Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.

    Good sealing
    All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.

    Good light transmission
    The system is composed of toughened glass with strong light transmittance.


    Modular UPS

    According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power.

    Technical Features


    Intelligent Fire Safe System

    Alerts personnel and drops ceiling panels based on temperature to enable fire suppressions system in the room toextinguish the fire. Once fire signal alarm in room, the top plate will open automatically, and fire extinguishing gasesan enter the aisle.


    Efficiency Flexibility

    Increases the capacity of the air conditioner by supplying a warmer return air temperature. It supports for varying aislewidths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment.


    Automatical Door Structure

    One-way locking door or safe slide doors secures the hot aisle while allowing for quick exit in case of emergency, thesliding door can be closed automatically, can be installed door access system and can be opened from inside to outside if an emergency occurs.

    Applicable Sence

    Single module Solution : It is suitable for small and medium data centers with power consumption less than 180KW and an area of less than 100 square meters. For data center needs of small and medium enterprises and branch offices of large enterprises.


    Multi-module solution: Through the flexible arrangement of multiple modules, a large-scale data center can be constructed. For the needs of large-scale data centers in IDC, large enterprises, financial centers, governments, military, supercomputer centers, education, medical and other industries


    Technical Specification

    Equipment SystemItemParameter
    SystemDimension1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
    Rack QuantityDual Row Racks:≤48,Single Row Racks:≤24
    RackDimensions600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
    Protection ClassIP20
    Enclosed AisleSkylight300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
    Power Supply and DistributionDimension600mm(W)*1200mm(D)*2000mm(H)
    UPS Power Supply380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
    Battery40AH~240AH/12V Valve Regulated Lead Acid Battery
    CoolingIndoor Unit Size300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
    Cooling CapacityCooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
    Power Supply3Phase 380VAC,50Hz
    Air SupplyFront Supply
    TypeEnclosed Hot/Cold Aisle
    ProtectionIP20
    Monitoring SystemMonitoringTemperature and humidity, smoke detection, smart access control, camera, water leakage alarm
    Equipment monitoringPower supply, battery, power distribution, air conditioning